Air Source Water Chiller for Water Cooling System

Product Details
Customization: Available
Certification: ISO9001, CE
Working Medium: 134A
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2014-12-02
Management System Certification
ISO9001:2015
  • Air Source Water Chiller for Water Cooling System
  • Air Source Water Chiller for Water Cooling System
  • Air Source Water Chiller for Water Cooling System
  • Air Source Water Chiller for Water Cooling System
  • Air Source Water Chiller for Water Cooling System
  • Air Source Water Chiller for Water Cooling System
Find Similar Products

Basic Info.

Model NO.
LT
Cooling Capacity
10kw-1000kw
MOQ
1
Guarantee Period
12 Month
Application
Cooling Water
Transport Package
Standard
Specification
Customized
Trademark
lytte
Origin
China
Production Capacity
50000PCS/Year

Packaging & Delivery

Package Size
1000.00cm * 1000.00cm * 1000.00cm
Package Gross Weight
200.000kg

Product Description

AIR SOURCE HEAT PUMP(WATER CHILLER)

Air Source Water Chiller for Water Cooling System
Parameter
 
Model No.:LTWFCDR- 10 20 30 40
Cooling capacity kW 33 65 98 131
Heating capacity kW 24.5 49 73.5 98
Heating capacity in Ambient Tmperature  7ºC kW 35 70 105 140
-7ºC kW 28 56 84 112
-12ºC kW 24.8 49.5 74.1 99
-15ºC kW 22 44 66 88
-20ºC kW 19.5 39 58.5 78
-25ºC kW 17.5 35 52.5 70
Power input Power supply 3/N/PE AC380V 50HZ
Cooling kW 9.6 19.2 28.8 38.4
Heating kW 9.1 18.2 27.3 36.4
heating in 7ºC kW 9.7 19.5 29.2 38.9
heating in -7ºC kW 9.6 19.3 28.9 38.5
heating in -12ºC kW 9.4 18.8 28.2 37.6
heating in -15ºC kW 9.1 18.2 27.3 36.4
heating in -20ºC kW 8.8 17.6 26.4 35.2
heating in -25ºC kW 8.4 16.8 25.2 33.6
Security settings Overload, high and low pressure, phase mismatch, water flow, oil pressure, freezing and high temperature etc
Compressor Type Full-hermetic low temperature high efficient EVI compressor
Quantity set 1 2 3 4
Refrigerant Type   R22 R407C
Filling qty kg 9 18 26 34
Qty of refigerant loops 1 2 3 4
Air side heat exchange fan High efficiency axial flow fan
Air side heat exchanger High efficiency copper tube string aluminum fin
Working ambient temperature -25ºC~43ºC
Evapoerator TYPE Tube in tube type High efficient shell and tube heat exchanger
Water flow rate m3/h 6 12 18 24
Pressure loss kPa 34.7 38.3 42.5 45.5
Interface size(DN) mm 50 65 80 80
Out dimension Length mm 1383 2264 3500 2294
Width mm 1231 1280 1360 2464
  Height mm 1710 1814 1900 1940
Weight kg 560 770 1200 1550
Noise dB(A) ≤68
Note:
1.Heating capicity based on the water ut temperatue 441ºC, while ambient temperature is -12ºC(Dry bulb),-14ºC(Wet bulb)
2.Cooling capicity based on the water in/out temperatue 12ºC/7ºC, while ambient temperature is 35ºC;
3.Users should prepare pump and power control box according to the design of system
4.Refrigerant R410a is optional
 
Model No.:LTWFCDR- 3 5 5 6 7 10
Cooling capacity kW 7.2 12.5 13.3 14 17.3 24.8
Heating capacity kW 8.4 14.5 15.5 17 19 29
Nominal heating capacity kW 5.7 8.7 9.5 11.6 12.8 19.56
Power input Power supply 1/N/PE AC220V 50HZ 3/N/PE AC380V 50HZ
Cooling kW 2.5 4.6 4.9 5.1 6.2 9.1
Heating kW 2.3 4.2 4.5 4.9 5.3 8.5
Nominal heating kW 2.7 4.1 4.4 5.5 6 9
Rated current A 12.5 23 9.8 10.2 12.4 18.2
Security settings Overload, high and low pressure, phase mismatch, water flow, oil pressure, freezing and high temperature etc
Compressor Type Full-hermetic ultra low temperature EVI compressor  
Quantity set 1 1 1 1 1 2
Refrigerant Type   R22 R407C R410A  
  Filling qty kg 2.6 3.5 3.8 4.2 4.5 3.5*2
Qty of refigerant loops 1 1 1 1 1 2
Air side heat exchange fan High efficiency axial flow fan
Air side heat exchanger High efficiency copper tube string aluminum fin
Working ambient temperature -25ºC~43ºC
Evapoerator TYPE High efficient heat exchanger
Water flow rate m3/h 1.24 2.15 2.29 2.41 2.98 4.27
Pressure loss kPa 46 46 46 46 46 46
Interface size(DN) mm 25 25 25 25 32 32
Out dimension Length mm 830 1110 1110 1340 1340 1540
Width mm 490 490 490 540 540 800
  Height mm 1160 1410 1410 1400 1400 1600
Weight kg 100 155 155 180 215 340
Air blow direction side side side side side up
Noise dB(A) 54 56 56 ≤57 ≤58 60
Note:
1.Heating capicity based on the water in/out temperatue 40ºC/45ºC, while ambient temperature is 7ºC(Dry bulb),6ºC(Wet bulb)
2.Cooling capicity based on the water in/out temperatue 12ºC/7ºC, while ambient temperature is 35ºC;
2.Nominal Heating capicity based on the water out temperature 41 ºC while ambient temperature is -12ºC(Dry bulb),-14ºC(Wet bulb)
3.Users should prepare pump and power control box according to the design of system
Air Source Water Chiller for Water Cooling System
Air Source Water Chiller for Water Cooling System
Air Source Water Chiller for Water Cooling System

Air Source Water Chiller for Water Cooling SystemAir Source Water Chiller for Water Cooling SystemAir Source Water Chiller for Water Cooling System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier